Product features;
■ Use for online testing;
The fastest speed is less than 5s/ pieces.
The placing requirements of the tested samples are low, and no precise adjustment is needed to meet the requirements of the online test.
Low environmental requirements, the general industrial environment can be used.
Open communication interface, you can cooperate with automated devices to achieve online detection, but also provide a complete automation solutions.
■ Multi point non-contact measurement with high accuracy;
Non contact detection, to avoid damage to the workpiece surface.
Ordinary workpieces can be detected from tens to hundreds of thousands of points.
Low environmental requirements, the general industrial environment can be used.
Open communication interface, you can cooperate with automated devices to achieve online detection, but also provide a complete automation solutions.
■ Finishing work instruction to improve efficiency;
According to the actual analysis of the results of follow-up processing guidance, so that operators can immediately clear how to process the next step.
■ Wide range of inspection, low size limit;
Material can be detected transparent glass, silicon wafers, silicon carbide and other spherical surface with mirror effect.■ The product is easy to use;
Basic type, standard type and high precision type equipment only need 3 steps to complete the measurement operation.
Both intelligent and automatic type have the function of "one key measurement", which can be completed by one step operation.
Serial Name |
Basic Type |
Standard Type |
High Sperm Type |
Intelligent |
Automatic Type |
|
SHF-CMA |
SHF-CMB |
SHF-CMC |
SHF-CMS |
SHF-CMV |
||
Function |
Curvity Radius Detection |
● |
● |
● |
● |
● |
Surface 3D Distribution |
|
|
● |
● |
● |
|
Auxiliary Machining Function |
|
|
● |
● |
● |
|
One Key Measuring Function |
|
|
|
● |
● |
|
Two-way Adjustment Platform |
|
● |
● |
● |
● |
|
Accuracy |
Curvity Accuracy |
5‰-10‰ |
5‰-10‰ |
1‰ |
1‰ |
1‰ |
Detection Range |
Outline Size(单位,mm) |
10x10~750x600 |
10x10~750x600 |
10x10~750x600 |
10x10~750x600 |
≥10x10 |
Concave Surface R(mm) |
≥20 |
≥20 |
≥20 |
≥20 |
≥20 |
|
Convex Surface R(mm) |
≥20 |
≥20 |
≥20 |
≥20 |
≥20 |
|
Reflectivity |
≥4% |
≥1% |
≥1% |
≥1% |
≥1% |
|
Lens Material |
Non Transparent Material |
Unlimited |
Unlimited |
Unlimited |
Unlimited |
|
Image System |
Image Acquisition System |
ATIAS-B |
ATIAS-B |
ATIAS |
ATIAS |
ATIAS |
Maximum Collection Pixels |
30W |
30W |
130W |
130W |
130W |
|
Minimum Acquisition Time |
3s |
3s |
5s |
5s |
5s |
|
Image Processing System |
ATIMP-V1.1 |
ATIMP-V1.1 |
ATIMP pro-V1.1 |
ATIMP pro-V1.1 |
ATIMP pro-V1.1 |
|
Fastest Processing Time |
2s |
2s |
3s |
3s |
3s |
|
Data Analysis System |
Judgment Of Standard Value (Judgment Of Cualified product) |
|
|
|
● |
● |
Yield Statistics |
|
|
|
● |
● |
|
Real Time Statistics And Display Of Good Yield |
|
|
|
● |
● |
|
Automatic Data Storage |
|
|
|
● |
● |
|
Online Detection Function |
Automatic Access System |
|
|
|
|
AATS |
Data Interface |
|
|
|
● |
● |
|
Environment Condition |
Temperature |
10℃-40℃ |
10℃-40℃ |
10℃-40℃ |
10℃-40℃ |
10℃-40℃ |
Humidity |
10%-80% |
10%-80% |
10%-80% |
10%-80% |
10%-80% |